GME Supply is North America's Premier Outfitter of fall protection, safety equipment, and gear for at-height workers, industry, and construction.

1391 E Boone Industrial Blvd
Columbia, MO 65202
(718) 210-3913

Home > Manufacturers > ZRC Worldwide > ZRC 221 Low VOC Cold Galvanizing Compound - 1 Gallon

Model#: 50003

Stock#: ZR-50003

 

ZRC 221 Low VOC Cold Galvanizing Compound - 1 Gallon

ZR-50003

$703.99 Sale price: $703.99 CS (2)

THIS ITEM SHIPS FOR FREE!
Get It By Dec 23

  • 40% lower levels of volatile organic compounds than traditional cold galv
  • Excellent for use in VOC-restricted areas
  • Unlike hot-dip galvanizing, ZRC 221 is portable, flexible protection that can be applied in a variety of formats.

ZRC 221 Low VOC Cold Galvanizing Compound - 1 Gallon

The ZRC 221 Low VOC Cold Galvanizing Compound is the newest innovation in zinc-rich technology. It offers the same superior performance of traditional cold galv with 40% lower levels of volatile organic compounds — a more environmentally friendly protection option.

With its unique formulation, ??ZRC 221 Cold Galvanizing Compound is excellent for use in VOC-restricted areas. ZRC-221 may be used without a top coat in place of hot-dip galvanizing. Also used as a high-performance base coat with a variety of topcoats. Its specially formulated for:

  • Galvalumeand Zinc Metallizing: ZRC 221 can be used for Galvalume and zinc metalizing projects.
  • Weldments Repair: Can be used to repair weldments.
  • Inorganic Zinc Coatings Repair: ZRC is also effective for inorganic zinc coatings repair.
  • Long-Term Protection: It’s proven to be effective long-term protection for: structural steel, water and waste facilities, power plants, transmission towers and antennae, steel decking and bridges, and numerous OEM uses.
  • Hot-Dip Galvanizing Repair & Regalvanizing: It’s a flexible option for repair of worn hot-dip galvanized materials.

Features:

  • 40% lower levels of volatile organic compounds than traditional cold galv
  • Excellent for use in VOC-restricted areas
  • Unlike hot-dip galvanizing, ZRC 221 is portable, flexible protection that can be applied in a variety of formats.
  • Excellent for reducing VOC emissions in restricted areas/production facilities
  • 92% zinc in the dry film using only Type III “ultra pure” ASTM-D-520 zinc
  • ISO 9001 registration assures the highest quality consistently
  • Meets and exceeds the performance requirements of Fed. Spec.
  • DOD-P-21035A (Galvanizing Repair Spec); MIL-P-26915A (USAF Zinc Dust Primer); ASTM Des. A-780 (Standard Practice for Repair of Damaged Hot-Dip Galvanized Coatings); SSPC-Paint 20 (Specification for Zinc-Rich Primer)
  • Passes 3,000 hours salt spray testing without failure (ASTM Des. B117)
  • Passes Preece Test (ASTM Des. A239) for hot-dip galvanizing

Flexible Application Formats

Unlike hot-dip galvanizing, ZRC 221 is portable, flexible protection that can be applied in a variety of formats.

  • Brush, Roller, and Aerosol: Apply as received in the container. For brush application, we recommend only 100% Natural Chinese Bristle brushes. For roller application, we recommend rollers with a 3/8” nap, made of mohair or lambs wool (sheepskin).
  • Spray (Low Pressure Compressor): ZRC can also be applied as a spray.
    • Atomized Air Pressure:  50 psi (1.3 kg/cm²)
    • Fluid Pressure: 15 to 20 psi (0.4-0.6 kg/cm²)
    • Orifice of Tip: 0.080 inches (0.20 cm)
    • Viscosity Reduction: 5:1 ZRC-221 : parachloro-triflouromethyl-benzene (vol)
  • Spray (Airless): Recommended Procedure: Connect hose directly to pump ensuring a hose length of 50 ft. max. Use the least pressure possible. Start at 1500 lbs. (680 kg) and increase as required for good spraying.
    • Pump: 30:1 Ratio
    • Hose: 1/2" (1.3 cm)(I.D.) Airless Type
    • Orifice of Tip: 60° - .026 in. (0.07 cm)
    • Type of Tip: Tungsten carbide, reversing
    • Filter Screens: Complete removal is recommended. However, if screens are employed, use no less than 30 mesh.
    • Viscosity: No reduction required

Specifications:

  • SSPC Paint Specification 20 – Zinc-Rich Coating: Type II – Organic; Level 1 – equal to or greater than 92% zinc dust by weight present in the dried film
  • Zinc Dust Content - ASTM D 520 Type III Zinc Dust — .002% maximum lead by weight
  • VOC Content — ASTM D 3960, 221 g/l (3.3 lbs per gallon) maximum

Testing Data:

  • Meets and exceeds the performance requirements of Fed. Spec. DOD-P-21035A, formerly MIL-P-21035 (Galvanizing Repair Spec.)
  • Meets and exceeds the performance requirements of Fed. Spec. MIL-P-26915A (USAF Zinc Dust Primer)
  • Passes 3,000 hours salt spray testing without failure** (ASTM Des. B117)
  • Passes Preece Test (ASTM Des. A239) for hot-dip galvanizing
  • Resists intermittent dry-heat temperatures up to 750°F
  • Meets and exceeds ASTM Des. A-780 (Standard Practice for Repair of Damaged Hot-Dip Galvanized Coatings)
  • Meets and exceeds SSPC-Paint 20 (Specification for Zinc-Rich Primer)

 

 

ZR-50003

Color: Battleship Grey
Manufacturer: ZRC Worldwide
Weight: 25.00