GME Supply is North America's Premier Outfitter of fall protection, safety equipment, and gear for at-height workers, industry, and construction.

1391 E Boone Industrial Blvd
Columbia, MO 65202
(718) 210-3913

Home > GME Supply Root > Devices & Testing > Testing & Detecting > Fluke 381 Remote Display True RMS AC/DC Clamp Meter with iFlex

Model#: 381

Stock#: FLK-381

UPC/GTIN/EIN: 095969537483

Fluke 381 Remote Display True RMS AC/DC Clamp Meter with iFlex

FLK-381

$895.99 Sale price: $895.99

THIS ITEM SHIPS FOR FREE!
Get It By Nov 27

  • Wireless technology allows the display to be carried up to 30 ft. away from the point of measurement with measurement accuracy
  • A removable magnetic display can be mounted where it is easily seen
  • iFlex Flexible Current Probe expands the measurement range to 2500 A AC

Fluke 381 Remote Display True RMS AC/DC Clamp Meter with iFlex

Now one technician can do jobs that would otherwise require two people. Clamp the Fluke 381 around a conductor, remove the display, and walk across the room to operate controls or remove protective equipment, all while watching real-time readings.

The iFlex Flexible Current Probe (included) expands the measurement range to 2500 A AC while providing increased display flexibility. With a cord that runs 6 feet, you can finally measure those tight spaces, awkward-sized conductors, and disorganized wires.

What's in the Box:

  • 381 Remote Display Clamp Meter
  • (1 pair) TL75 test leads
  • (1 pair) AC175 alligator clips
  • 18-inch iFlex flexible current probe
  • Soft carrying case

Features:

  • Wireless technology allows the display to be carried up to 30 ft. away from the point of measurement with measurement accuracy
  • A removable magnetic display can be mounted where it is easily seen
  • iFlex Flexible Current Probe expands the measurement range to 2500 A AC
  • CAT IV 600 V, CAT III 1000 V
  • Integrated low pass filter and state-of-the-art signal processing allows for use in noisy electrical environments while providing stable readings
  • Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
  • Ergonomic design fits in your hand and can be used while wearing protective equipment
  • Radio transmitter automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement
  • Three-year warranty

Specifications:

  • Electrical Specifications:
    • Range: 999.9 A
    • Resolution: 0.1 A
    • Accuracy:
      • 2% ± 5 digits (10-100 Hz)
      • 5% ± 5 digits (100-500 Hz)
  • Crest Factor (50/60 Hz):
    • 3 @ 500 A
    • 2.5 @ 600 A
    • 1.42 @ 1000 A
    • Add 2% for C.F. > 2
  • AC Current via Flexible Current Probe:
    • Range: 999.9 A / 2500 A (45 Hz – 500 Hz)
    • Resolution: 0.1 A / 1 A
    • Accuracy: 3% ± 5 digits
    • Crest Factor (50/60 Hz):
      • 3.0 at 1100 A
      • 2.5 at 1400 A
      • 1.42 at 2500 A
      • Add 2% for C.F. > 2
  • DC Current
    • Range: 999.9 A
    • Resolution: 0.1 A
    • Accuracy: 2% ± 5 digits
  • AC Voltage
    • Range: 600 V /1000 V
    • Resolution: 0.1 V / 1 V
    • Accuracy: 1.5% ± 5 digits (20 – 500 Hz)
  • DC Voltage
    • Range: 600.0 V /1000 V
    • Resolution: 0.1 V / 1 V
    • Accuracy: 1% ± 5 digits
  • Frequency – Via Jaw: 
    • Range: 5.0 – 500.0 Hz
    • Resolution: 0.1 Hz
    • Accuracy: 0.5% ± 5 digits
    • Trigger Level:
      • 5 – 10 Hz, ≥ 10 A
      • 10 – 100 Hz, ≥ 5 A
      • 100 – 500 Hz, ≥ 10 A
  • Frequency via Flexible Current Probe:
    • Range: 5.0 to 500.0 Hz
    • Resolution: 0.1 Hz
    • Accuracy: 0.5% ± 5 digits
    • Trigger Level:
      • 5 to 20 Hz, ≥ 25 A
      • 20 to 100 Hz, ≥ 20 A
      • 100 to 500 Hz, ≥ 25 A
  • Resistance:
    • Range: 600 Ω/6 kΩ/60 kΩ
    • Resolution: 0.1 Ω/1 Ω/10 Ω
    • Accuracy: 1% ± 5 digits
  • Mechanical Specifications:
    • Size (L x W x H): 277 x 88 x 43 mm (55 mm for remote unit)
    • Weight: 350 g
    • Jaw Opening: 34 mm
    • Flexible Current Probe Diameter: 7.5 mm
    • Flexible Current Probe Cable Length (head to electronics connector): 1.8 m
  • Environmental Specifications:
    • Operating Temperature: -10°C to +50°C
    • Storage Temperature: -40°C to +60°C
    • Operating Humidity:
      • Non condensing (< 10°C)
      • ≤ 90% RH (at 10°C to 30°C)
      • ≤ 75% RH (at 30°C to 40°C)
      • ≤ 45% RH (at 40°C to 50°C)
      • (Without Condensation)
    • Operating Altitude: 2,000 meters
    • Storage Altitude: 12,000 meters
    • EMI, RFI, EMC, RF:
      • EN 61326-1:2006, EN 61326-2-2:2006
      • ETSI EN 300 328 V1.7.1:2006
      • ETSI EN 300 489 V1.8.1:2008
      • FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
      • FCCID: T68-F381
      • RSS-210 IC: 6627A-F381
    • Temperature Coefficients: Add 0.1 x specified accuracy for each degree C above 28°C or below 18°C
    • Wireless Frequency: 2.4 GHz ISM Band 10 meter range
    • Safety Compliance:
      • ANSI/ISA S82.02.01:2004
      • CAN/CSA-C22.2 No. 61010-1-04
      • IEC/EN 61010-1:2001 to 1000V CAT III, 600V CAT IV.
  • Double Insulation Clearance: Per IEC 61010-2-032
  • Double Insulation Creepage: Per IEC 61010-1

FLK-381

Manufacturer: Fluke

Reviews